同一机柜其它机器都在千兆模式但有几台却是百兆,调整速度后还自动降速到百兆.
最后让机房换了网线立马解决问题,数据库的进程排队也降低了
查看网卡信息,网卡支持千兆但工作在百兆.
ethtool eth2
Advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
Advertised pause frame use: No
Advertised auto-negotiation: Yes
Speed: 100Mb/s
Duplex: Full
调整到千兆
ethtool -s eth2 speed 1000 duplex full
tail /var/log/messages
Oct 23 10:17:22 C1g kernel: e1000e: eth2 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: None
Oct 23 10:17:23 C1g kernel: e1000e: eth2 NIC Link is Down
Oct 23 10:17:33 C1g kernel: e1000e: eth2 NIC Link is Up 100 Mbps Full Duplex, Flow Control: None
Oct 23 10:17:33 C1g kernel: 0000:03:00.1: eth2: 10/100 speed: disabling TSO
又变回到百兆
ethtool备注
ethtool ethX //查询ethX网口基本设置
ethtool –h //显示ethtool的命令帮助(help)
ethtool –i ethX //查询ethX网口的相关信息
ethtool –d ethX //查询ethX网口注册性信息
ethtool –r ethX //重置ethX网口到自适应模式
ethtool –S ethX //查询ethX网口收发包统计
ethtool –s ethX [speed 10|100|1000]\ //设置网口速率10/100/1000M
[duplex half|full]\ //设置网口半/全双工
[autoneg on|off]\ //设置网口是否自协商
No Responses (yet)
Stay in touch with the conversation, subscribe to the RSS feed for comments on this post.